EDT SERIES ADVANTAGES:·OPERATIONAL SAFETY
·ANTI-HUMIDITY RESISTANCE
·PHASE PROTECTION
·VOLTAGE PROTECTION
·OVERLOAD PROTECTION
·OPERATIONAL DIAGNOSIS
·PASSWORD PROTECTION WORKING ENVIRONMENT
ANTI-CORROSION PROTECTION:
Epoxy resin enclosure meets NEMA 4X, customer-special painting is available.
INGRESS PROTECTION:
IP67 is standard, IP68 is optional. The definition of IP68 is:
Depth of water: Maximum 15 m under water level.
Duration of continuous immersion in water: Max.(72 hours).
FIREPROOFING GRADE:
High temperature fireproof enclosure meets requirements in different situation.
It can be customized according to special needs.
EXPLOSION-PROOF RATING:
Ex d IIC T6 design and IECEx, ATEX certifications
which satisfy the reqirements in hazardous locations.
AMBIENT TEMPERATURE:
Temperature range is from -30 ºC to 70 ºC (-22 ºF to +158 ºF).
RELATIVE HUMIDITY:
≤ 95 % (at 25 ºC /275 ºF).
EXPLOSION RESISTANT SPECIFICATION
EMT11-44 series Basic (B) Integral (M) Integration (Y) Intelligent ( I )Super Intelligent (S)
CNEX Authentication: Ex d IIB T4 Gb/Ex Td A21 IP67 T130ºC temperature:-20~+70ºC Optional: -40~+70ºC
Ex d IIC T4 Gb/Ex Td A21 IP67 T130ºC temperature:-20~+70ºC Optional: -40~+70ºC
Ex d IIB T6 Gb/Ex Td A21 IP67 T80ºC temperature:-20~+55ºC Optional: -40~+55ºC
Ex d IIC T6 Gb/Ex Td A21 IP67 T80ºC temperature:-20~+55ºC Optional: -40~+55ºC
CNEX:GB3836.1,GB3836.2,GB12476.1 Optional:IP68(GB12476.1)
EMT11-44 Series Model Selection
AC 220V/AC 380V/AC 440V/AC 480V 3 phase on-off type series
Speed RPM | 50Hz rpm | 18 | 24 | 36 | 48 | 72 | 96 | 144 | 192 |
60Hz rpm | 21 | 29 | 43 | 57 | 86 | 115 | 173 | 230 |
Model | Output Torque |
EMT11 | N.m | 35 | 35 | 35 | 35 | 35 | 35 | 30 | 25 |
Ibf.ft | 26 | 26 | 26 | 26 | 26 | 26 | 22 | 18 |
EMT12 | N.m | 80 | 80 | 80 | 70 | 50 | 40 | 35 | 30 |
Ibf.ft | 59 | 59 | 59 | 52 | 37 | 29 | 26 | 22 |
EMT13 | N.m | 105 | 105 | 100 | 90 | 60 | 50 | 40 | 35 |
Ibf.ft | 77 | 77 | 74 | 66 | 44 | 37 | 29 | 26 |
EMT21 | N.m | 200 | 200 | 200 | 200 | 170 | 150 | 100 | 60 |
Ibf.ft | 147 | 147 | 147 | 147 | 125 | 111 | 74 | 44 |
EMT22 | N.m | 300 | 300 | 250 | 220 | 200 | 170 | 120 | 80 |
Ibf.ft | 221 | 221 | 184 | 162 | 147 | 125 | 88 | 59 |
EMT23 | N.m | 400 | 400 | 300 | 250 | 250 | 230 | 150 | 90 |
Ibf.ft | 295 | 295 | 221 | 184 | 184 | 170 | 111 | 66 |
EMT31 | N.m | 620 | 620 | 550 | 480 | 480 | 370 | 250 | 200 |
Ibf.ft | 457 | 457 | 406 | 354 | 354 | 273 | 184 | 147 |
EMT41 | N.m | 1050 | 1050 | 850 | 700 | 700 | 550 | 420 | 250 |
Ibf.ft | 774 | 774 | 627 | 516 | 516 | 406 | 310 | 184 |
EMT42 | N.m | 1500 | 1500 | 1300 | 1050 | 1050 | 750 | 650 | 550 |
Ibf.ft | 1106 | 1106 | 959 | 774 | 774 | 553 | 479 | 406 |
EMT43 | N.m | 2050 | 2050 | 1750 | 1400 | 1400 | 1050 | 880 | 750 |
Ibf.ft | 1512 | 1512 | 1291 | 1032 | 1032 | 774 | 649 | 553 |
EMT44 | N.m | 3000 | 3000 | 2050 | 1750 | 1750 | 1450 | 1360 | 1360 |
Ibf.ft | 2212 | 2212 | 1512 | 1291 | 1291 | 1069 | 1003 | 1003 |
Note:
1. Above torque is the maximum torque. Please contact us if in need of special torque or speed.
2. Designed according to EN 15714-2009, Class A & B. The working time is S2 ~ 15 min.
3. Products with a* means the speed inertia is larger. Therefore, directly driving the gate valves and other similar applications is not recommended. For multi- turn actuators with A-type lift nut connection mechanism, the maximum permissible shaft speed (output speed) must follow:
A. The maximum for gate valve is 500 mm/min.
B. For the cut-off valve is up to 250 mm/min (maximum 45 rpm).
4. Modulating duty is available for option; the intermittent duty is S4 ~ 25 % and up to 600 starts per hour.
AC 220V/AC 230V Single phase seriesSpeed RPM | 50Hz rpm | 18 | 24 | 36 | 48 | 72 | 96 |
60Hz rpm | 21 | 29 | 43 | 57 | 86 | 115 |
Model | Max. Output Torque |
EMT11 | N.m | 60 | 60 | 50 | 50 | 35 | 35 |
Ibf.ft | 44 | 44 | 37 | 37 | 26 | 26 |
EMT21 | N.m | 150 | 150 | 130 | 100 | 50 | 50 |
Ibf.ft | 111 | 111 | 96 | 74 | 37 | 37 |
EMT13 | N.m | 250 | 250 | 200 | 170 | 130 | 100 |
Ibf.ft | 184 | 184 | 147 | 125 | 96 | 74 |
Note:
1. Above torque is the maximum torque. Please contact us if in need of special torque or speed.
2. Designed according to EN 15714-2009, Class A & B. The working time is S2 ~ 15 min. AC 220V/AC 380V/AC 440V/AC 480V 3 phase on-off type series(unit:KW)
Speed | 18 | 24 | 36 | 48 | 72 | 96 | 144 | 192 |
EMT11 | 0.2 | 0.2 | 0.2 | 0.2 | 0.35 | 0.35 | 0.5 | 0.5 |
EMT12 | 0.35 | 0.35 | 0.35 | 0.35 | 0.35 | 0.35 | 0.6 | 0.6 |
EMT13 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.45 | 0.7 | 0.7 |
EMT21 | 1.1 | 1.1 | 1.1 | 1.1 | 1.1 | 1.1 | 1.5 | 1.5 |
EMT22 | 1.1 | 1.1 | 1.1 | 1.1 | 1.1 | 1.1 | 1.8 | 1.8 |
EMT23 | 1.25 | 1.25 | 1.25 | 1.25 | 2 | 2 | 2.3 | 2.3 |
EMT31 | 2.4 | 2.4 | 2.4 | 2.4 | 3 | 3 | 4 | 4 |
EMT41 | 3.5 | 3.5 | 3.5 | 3.5 | 3.5 | 3.5 | 6.5 | 6.5 |
EMT42 | 5.3 | 5.3 | 5.3 | 5.3 | 5.3 | 5.3 | 11 | 11 |
EMT43 | 7.5 | 7.5 | 7.5 | 7.5 | 7.5 | 7.5 | 15 | 15 |
EMT44 | 7.5 | 7.5 | 9 | 9 | 9 | 9 | 20 | 20 |
AC 220V/AC 230V Single phase series(unit:KW)Speed | 18 | 24 | 36 | 48 | 72 | 96 |
EMT11 | 0.3 | 0.3 | 0.4 | 0.4 | 0.4 | 0.4 |
EMT12 | / | 0.75 | / | 0.75 | 1 | 1 |
EMT21 | 0.75 | 0.75 | 1 | 1 | 1 | 1 |
EMT22 | / | 1.25 | / | 1.25 | 1.5 | 1.5 |
EMT31 | 1.25 | 1.25 | 1.5 | 1.5 | 1.5 | 1.5 |
AC 220V/AC 380V/AC 440V/AC 480V 3 phase modulating type series
Speed RPM | 50Hz rpm | 18 | 24 | 36 | 48 | 72 |
60Hz rpm | 21 | 29 | 43 | 57 | 86 |
Model | Output Torque | N.m | Ibf.ft | N.m | Ibf.ft | N.m | Ibf.ft | N.m | Ibf.ft | N.m | Ibf.ft |
EMT11 | Modulating Torque | 18 | 13 | 18 | 13 | 16 | 12 | 14 | 11 | 12 | 10 |
Max Torque | 35 | 26 | 35 | 26 | 31 | 23 | 28 | 21 | 25 | 19 |
EMT12 | Modulating Torque | 30 | 23 | 30 | 23 | 26 | 19 | 23 | 16 | 18 | 13 |
Max Torque | 60 | 45 | 60 | 45 | 50 | 37 | 45 | 33 | 35 | 26 |
EMT13 | Modulating Torque | 40 | 29 | 40 | 29 | 36 | 26 | 33 | 24 | 25 | 18 |
Max Torque | 80 | 59 | 80 | 59 | 72 | 53 | 65 | 48 | 50 | 37 |
EMT21 | Modulating Torque | 78 | 60 | 78 | 60 | 70 | 52 | 55 | 40 | 45 | 33 |
Max Torque | 160 | 118 | 160 | 118 | 140 | 104 | 110 | 81 | 90 | 67 |
EMT22 | Modulating Torque | 120 | 88 | 120 | 88 | 100 | 75 | 85 | 63 | 75 | 55 |
Max Torque | 240 | 177 | 240 | 177 | 200 | 148 | 170 | 126 | 150 | 111 |
EMT23 | Modulating Torque | 150 | 111 | 150 | 111 | 130 | 96 | 105 | 78 | 95 | 70 |
Max Torque | 300 | 221 | 300 | 221 | 260 | 192 | 210 | 155 | 190 | 140 |
EMT31 | Modulating Torque | 275 | 203 | 275 | 203 | 255 | 188 | 205 | 151 | 190 | 139 |
Max Torque | 550 | 406 | 550 | 406 | 510 | 376 | 410 | 302 | 380 | 278 |
Note:
1. Designed according to EN 15714-2009, Class C & D. With the standard startup frequency of 50 %, not exceeding 1200 starts per hour.
Please contact us for special inquiry.
2. Above modulating torque is 1/2 of the max torque.
PERFORMANCE:General Parameters | Torque Range | ▪ 35 - 3,000 Nm Direct Output |
Speed | ▪ 18,24,36,48,72 ,96,144,192(rpm) (please contact us for customization if in need of other voltages) |
Ambient Temperature | ▪ -30ºC~70ºC(-22 ºF~158ºF) Optional: -40ºC~60ºC(-40 ºF~140ºF) |
Anti-vibration Level | ▪ JB/T8219 |
Noise Level | ▪ Less than 75 dB within 1 m |
Electrical interface | ▪ Two NPT 3/4,One NPT1 1/2 (please contact us for customization if in need of other interface) |
Ingress Protection | ▪ IP67,Optional:IP68 The definition of IP68 is:Depth of water: Maximum 15m under water level.Duration of continuous immersion in water: Max.(72 hours). |
Connection size | ▪ ISO5210(Thrust type\ torque type)and JB2920(Three claw type) |
Mechanical Parameters | Motor Specifications | ▪ Class F, with thermal protector up to +135 ºC (+275 ºF) |
Working System | ▪ On-off Type: S2 ~ 15 min, no more than 600 times per hour start ▪ ModulatingType: S4 ~ 50 %, up to 600 triggers per hour ○ Optional: 1200 times per hour |
Applicable Voltage | ▪ 3 phase: AC 380 V (±10 %) /50/60 Hz (±5 %) 3 phase 3 wires ○ Optional: 1 phase AC 220 V (1...3 series) (please contact us for customization if in need of other voltages) |
Bus | ▪ N/A |
On/off Type Signal | Input | ▪ AC/DC 24 input ▪ AC 110/220 V input ▪ Optoelectronic isolation |
Signal Feedback | ▪ Local/remote contacts ▪ Integrated fault contact ▪ Close the valve contact ▪ Open the valve contact (contact capacity: 5 A at 250 V ac) ○ Optional: Opening torque signal contact Closing torque signal contact |
Malfunction Feedback | ▪ Integrated fault alarm: Power off, motor overheating, losing phase, over torque, lose signal, ESD, terminal output |
Modulating Type Signal | Input | ▪ Input signal: 4 ~ 20 mA; 0 ~ 10 V; 2 ~ 10 V ▪ Input impedance: 75 Ω (4 ~ 20 mA) |
Output | ▪ Input signal: 4 ~ 20 mA;0~10 V; 2 ~ 10 V ▪ Output impedance: ≤750 Ω (4 ~ 20 mA) (repeatability and linearity within ±1 %of full valve stroke) |
Signal Reverse | ▪ Support |
Loss Signal Mode Setting | ▪ Support |
Dead Zone | ▪ ≤2% |
Time Lag | ▪ 0.5s-10s(adjustable) |
Control mode | Indication | ▪ LCD screen disply ▪ Fully open/Fully close/remote/ fault indicator(digital display of the opening percentage) |
Operation Settings | ▪ Settings done without opening cover (menu settings by the remote control) ▪ Supporting stroke, maximum opening setting |
Local Control | ▪ Non-intrusive on site control knobs: Open/Close,Local/Remote/Off |
Others | Intelligently Analyze Data Records | ▪ N/A |
Other Function | ▪ Phase correction(3 phase power supply only) ▪ Alarm signal(local and remote included) ▪ Torque protection ▪ Motor overheat protection ▪ Moisture-resistant heater(anti-moisture device) ▪ Infrared remote control ○ Optional:Intrinsically safe remote control |
CERTIFICATE
CAPABILITYProcessing
Testing
VISITORS
EXHIBITIONSHOEVNDIYHOEVNDIY is the brand original from Canada and manufactured in China. This is guaranteed advance technology, reliable quality and economical valves to every client.
In accordance with CE, ISO9001, ISO14000 and SIL3, HOEVNDIY strictly control the product quality.
HOEVNDIY steps to offer innovation valves and services to keep projects operating efficiently and reliably.